Refractometer- J57TPN for Hospital Pharmacies to monitor IV Therapies and controlled substances.

The Rudolph Research J57TPN refractometer is intended for use in hospital pharmacies and Compounding Labs to monitor the quality of parenteral nutrition mixtures, Intravenous therapy (IV), and ensure compliance with USP<797>. It is also useful in preventing the diversion of narcotics, and other controlled materials. The J57TPN pharmacy refractometer provides a fast, easy to use way to check on materials returned from the operation theatre or incorrectly issued from the pharmacy.

Refractometer-J57TPN

Application - Compunding Pharmacies

The first decade of the 21st Century has seen dramatic changes in health system pharmacies. New regulations such as USP<797> are forcing compounding pharmacies to do quality checks that were previously only required of pharmaceutical manufacturers. The J57TPN refractometer from Rudolph Research Analytical is specifically designed the so the hospital pharmacy can comply with this new regulatory environment.

 

Drug Diversion Monitoring

The J57TPN also doubles as a refractometer to monitor potential drug diversion issues. Ever more strict laws mean a health system must be aware of what is happening with controlled substances. Measuring hospital operating theater returns and similar movements of controlled substances can be a key part of an organization’s policy on meeting these laws.

 

Automatic Measuring System

The Rudolph J57TPN refractometer features a fully automatic measuring system. The operator simply places the sample on the prism, presses a button and the result is displayed on a 7.5cm x 10cm back-lit digital LCD screen. There are no shadow lines to match and there is no eyepiece requiring operator determination or manual adjustment.

 

Pharmacy Relevant Calculations

The J57TPN has built-in comparison and calculations for fast and accurate measurements of substances. The user enters the % Dextrose and % Amino Acid and the refractometer will display both the calculated and measured result, making it easy for an operator to see if the material is within specification.

 

Automatic Electronic Temperature Control

Refractive Index (RI) is a temperature sensitive property. For many years pharmacies largely ignored this fact or used sugar based temperature correction. Pharmaceutical manufacturers who were constrained by USP guidelines were not able to ignore this as USP<831> clearly states that they had to measure at a controlled temperature, generally 20°C. Now that pharmacies are under similar pressure, temperature sensitivity also must be considered. Fortunately with the J57TPN, old style circulating water baths are a thing of the past and sucrose based mathematical approximations are not needed because of the instrument’s built in electronic heating and cooling which ensures the sample is measured at 20°C every time.

Principle