Quartz Plate Calibration Standard

Rudolph Research utilizes the highest calibration standards in the laboratory instruments industry.

Calibration

Rudolph Research Analytical Quartz Control Plates provide a permanent calibration standard for polarimeters and saccharimeters. Every Rudolph calibration standard is manufactured using extremely stable crystalline quartz which is manufactured and polished to specific planeness, parallelism, purity, and axis standards. These standards meet or exceed the specifications outlined on Page 61 of the National Institute for Standards and Technology (NIST) Circular C440 or as laid down by the International Commission for Uniform Methods of Sugar Analysis (ICUMSA). Each Quartz Plate comes complete with a label showing calibration at 11 different wavelengths (Picture G), a protective box and a NIST Traceable Certificate.

 

Selecting a Quartz Calibration Standard

Calibration-2

Any rotation is available but generally available stock rotations are listed below.Quartz Plates come in single and dual versions. Single Quartz Plates (Picture E) have a single rotation value at each wavelength and are calibrated in °Arc (Optical Rotation) and °ISS/°Z (Sugar Degrees). Dual Plates are also calibrated in °Arc and °ISS, but have three rotation values at each wavelength (Picture F). This is possible because each plate is made up of one left or levo turning Quartz Plate (i.e. -28° Arc) and one right or dextro turning plate (i.e. +30° Arc) which may be used separately or together for a combined rotation of 2° Arc (30°-28°) see Picture H below. Every Rudolph Research Analytical Quartz Plate is manufactured to a reported uncertainty of ±0.002° Arc at 589. Please contact the factory for the Quartz Accessory Plate that is best suited for your needs.

 

Selecting a Quartz Plate

Any rotation is available. Quartz Plates come in single and dual versions. Single Quartz Plates (See Figure 1) have a single rotation value at each wavelength and are calibrated in °Arc (Optical Rotation) and °ISS/°Z (Sugar Degrees). Dual Plates are also calibrated in °Arc and °ISS, but have three rotation values at each wavelength (See Figure 2). This is possible because each plate is made up of one left or levo turning Quartz Plate (i.e. -28° Arc) and one right or dextro turning plate (i.e. +30° Arc) which may be used separately or together for a combined rotation of 2° Arc (30°-28°). Please contact the factory for the Quartz Plate that is best suited for your needs.

Principle
  • Stable Micro Systems
  • Rudolph Research Analytical
  • Novasina
  • 3NH Colorimeter
  • CENTEC
  • Triowin